EN : up to 300V.A, enclosed IP67 (made to order, non stocked items)

  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.16A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.0kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.25A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.5kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.5A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 2.1kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 1.0A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 4.8kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.16A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.0kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.25A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.5kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.5A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 2.1kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 1.0A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 4.8kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.16A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.0kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.25A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.5kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.5A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 2.1kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 1.0A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 4.8kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 1.6A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 5.4kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.125A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.5kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.25A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 2.1kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.5A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 4.8kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.8A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 5.4kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.1A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.0kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.125A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.5kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.25A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 2.1kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.1A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.0kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.125A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.5kg
  • EN safety isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, safety isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.25A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 2.1kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.1A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.0kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.125A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 1.5kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.25A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 85mm, w. 80mm, d. 250mm, 2.1kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.5A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 4.8kg
  • EN isolating
    • Intended applications: Fixed associated control & power transformers.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Primary fuse fitted T 0.8A (slow blow)
    • Construction: Enclosed ABS IP67
    • Connections: Primary input terminals (fused) / secondary output terminals.
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
    • Dimensions: h. 130mm, w. 150mm, d. 250mm, 5.4kg