NT : up to 120mA, neon HV, IP44 (non stock - indent items)

  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 2.0kvac centre tap earthed (1kvac - E - 1kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 46mm, L. 260mm, W. 74mm, 2.1kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 3kvac centre tap earthed (1.5kvac - E - 1.5kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 71mm, L. 247mm, W. 76mm, 2.9kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 4.0kvac centre tap earthed (2.0kvac - E - 2.0kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 73mm, L. 247mm, W. 76mm, 3.0kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 5.0kvac centre tap earthed (2.5kvac - E - 2.5kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 82mm, L. 247mm, W. 76mm, 3.7kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 6.0kvac centre tap earthed (3.0kvac - E - 3.0kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 84mm, L. 247mm, W. 76mm, 3.8kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 7.0kvac centre tap earthed (3.5kvac - E - 3.5kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 87mm, L. 270mm, W. 92mm, 4.8kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 8.0kvac centre tap earthed (4.0kvac - E - 4.0kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 87mm, L. 270mm, W. 92mm, 4.9kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 9.0kvac centre tap earthed (4.5kvac - E - 4.5kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 92mm, L. 270mm, W. 92mm, 5.4kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 10kvac centre tap earthed (5.0kvac - E - 5.0kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 92mm, L. 270mm, W. 92mm, 5.5kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 10kvac centre tap earthed (5.0kvac - E - 5.0kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 116mm, L. 310mm, W. 107mm, 9.6kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 12kvac centre tap earthed (6.0kvac - E - 6.0kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 95mm, L. 290mm, W. 95mm, 6.5kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 15kvac centre tap earthed (7.5kvac - E - 7.5kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 100mm, L. 305mm, W. 107mm, 7.5kg
  • NT isolating
    • Intended applications: Fixed HV neon sign transformer.
    • Classification: Class 1, isolating short circuit proof.
    • Protection: Inherently current limiting (short circuit proof).
    • Construction: Resin block IP44.
    • Connections: Primary input terminals / secondary output terminals.
    • Secondary winding 15kvac centre tap earthed (7.5kvac - E - 7.5kvac)
    • Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
    • Manufactured standard: ASNZS 61050 (IEC 61050).
    • Dimensions: H. 122mm, L. 355mm, W. 140mm, 15kg